Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38704861

RESUMO

OBJECTIVES: The objective of this study was primarily to compare 4D flow magnetic resonance imaging (MRI) metrics in the ascending aorta (AA) of patients with right-left fusion type bicuspid aortic valve (RL-BAV) and repaired CoA to RL-BAV without CoA. Metrics of patients with RL-BAV were also compared to the matched group of patients with common tricuspid aortic valve (TAV). METHODS: 11 patients with RL-BAV and CoA, 11 patients with RL-BAV without CoA, and 22 controls with TAV, were investigated. Peak velocity (cm/s), peak flow (ml/s), and flow displacement (FD, %) were analyzed at five pre-defined AA levels. In addition, regional wall shear stress (WSS, mN/m2), circumferential WSS (WSSc), and axial WSS (WSSa) at all levels were quantified in six sectors of the aortic circle. Averaged WSS values on each level (WSSavg, WSSc, avg and WSSa, avg) were calculated as well. RESULTS: Peak velocity at the proximal tubular AA was significantly lower in BAV and CoA group (p = 0.047) compared to BAV without CoA. In addition, the WSSa, avg was found to be higher for the BAV and CoA group at proximal AA respectively (p = 0.040). No other significant differences were found between these groups.BAV group's peak velocity was higher at every level (p < 0.001-0.004) compared to TAV group. FD was significantly higher for the BAV group at every level (p < 0.001) besides at the most distal level. All averaged WSS values were significantly higher in BAV patients in distal AA (p < 0.001-0.018). CONCLUSIONS: Repaired CoA does not relevantly alter 4D flow metrics in the AA of patients with RL-BAV. However, RL-BAV majorly alters flow dynamics in the AA when compared to patients with TAV. TRIAL INFORMATION: https://www.clinicaltrials.gov/study/NCT05065996, Unique Protocol ID 5063566.

2.
Front Med (Lausanne) ; 9: 1018208, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36569136

RESUMO

Background: Vascular endothelial growth factors (VEGFs) are major regulators of intratumoral angiogenesis in ovarian cancer (OVCA). Overexpression of VEGFs is associated with increased tumor growth and metastatic tendency and VEGF-targeting therapies are thus considered as potential treatments for OVCA. Here, we examined the antiangiogenic and antitumoral effects on OVCA of adeno-associated virus 8 (AAV8)-mediated expression of soluble VEGF receptors (sVEGFRs) sVEGFR2 and sVEGFR3 together with paclitaxel and carboplatin chemotherapy. Materials and methods: Immunodeficient mice were inoculated with human OVCA cell line SKOV-3m. Development of tumors was confirmed with magnetic resonance imaging (MRI) and mice were treated with gene therapy and paclitaxel and carboplatin chemotherapy. The study groups included (I) non-treated control group, (II) blank control vector AAV8-CMV, (III) AAV8-CMV with chemotherapy, (IV) AAV8-sVEGFR2, (V) AAV8-sVEGFR3, (VI) AAV8-sVEGFR2 and AAV8-sVEGFR3, and (VII) AAV8-sVEGFR2 and AAV8-sVEGFR3 with chemotherapy. Antiangiogenic and antitumoral effects were evaluated with immunohistochemical stainings and serial MRI. Results: Reduced intratumoral angiogenesis was observed in all antiangiogenic gene therapy groups. The combined use of AAV8-sVEGFR2 and AAV8-sVEGFR3 with chemotherapy suppressed ascites fluid formation and tumor growth, thus improving the overall survival of mice. Antitumoral effect was mainly caused by AAV8-sVEGFR2 while the benefits of AAV8-sVEGFR3 and chemotherapy were less prominent. Conclusion: Combined use of the AAV8-sVEGFR2 and AAV8-sVEGFR3 with chemotherapy reduces intratumoral angiogenesis and tumor growth in OVCA mouse model. Results provide preclinical proof-of-concept for the use of soluble decoy VEGFRs and especially the AAV8-sVEGFR2 in the treatment of OVCA.

3.
NMR Biomed ; 34(4): e4483, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33543563

RESUMO

MRI is a common method of prostate cancer diagnosis. Several MRI-derived markers, including the apparent diffusion coefficient (ADC) based on diffusion-weighted imaging, have been shown to provide values for prostate cancer detection and characterization. The hypothesis of the study was that docetaxel chemotherapy response could be picked up earlier with rotating frame relaxation times TRAFF2 and TRAFF4 than with the continuous wave T1ρ , adiabatic T1ρ , adiabatic T2ρ , T1 , T2 or water ADC. Human PC3 prostate cancer cells expressing a red fluorescent protein were implanted in 21 male mice. Docetaxel chemotherapy was given once a week starting 1 week after cell implantation for 10 randomly selected mice, while the rest served as a control group (n = 11). The MRI consisted of relaxation along a fictitious field (RAFF) in the second (RAFF2) and fourth (RAFF4) rotating frames, T1 and T2 , continuous wave T1ρ , adiabatic T1ρ and adiabatic T2ρ relaxation time measurements and water ADC. MRI was conducted at 7 T, once a week up to 4 weeks from cell implantation. The tumor volume was monitored using T2 -weighted MRI and optical imaging. The histology was evaluated after the last imaging time point. Significantly reduced RAFFn, T1ρ, T2ρ and conventional relaxation times 4 weeks after tumor implantation were observed in the treated tumors compared with the controls. The clearest short- and long-term responses were obtained with T1 , while no clear improvement in response to treatment was detected with novel methods compared with conventional methods or with RAFFn compared with all others. The tumor volume decreased after a two-week time point for the treated group and increased significantly in the control group, which was supported by increasing red fluorescent light emission in the control tumors. Decreased relaxation times were associated with successful chemotherapy outcomes. The results indicate altered relaxation mechanisms compared with higher dose chemotherapies previously published.


Assuntos
Docetaxel/uso terapêutico , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/tratamento farmacológico , Animais , Difusão , Modelos Animais de Doenças , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Carga Tumoral , Água
4.
NMR Biomed ; 32(8): e4108, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31112347

RESUMO

AIMS: In calcific aortic valve disease (CAVD), progressive valvular sclerosis and calcification cause narrowing of the orifice and an impairment of the valve's function. We applied high-resolution cine-MRI to perform quantitative analysis of the dynamics of the aortic valve in a mice model of CAVD. METHODS AND RESULTS: LDLr-/- ApoB100/100 mice were fed a Western diet (WD) or a standard diet (control) for 22 weeks. The mice were imaged in a 7 T horizontal MRI scanner, and aortic valve dynamics was examined by imaging the cross-section of the aorta at valve level using cine sequences. From these images, the area of the aortic valve orifice was determined during the heart cycle. MRI results were compared with echocardiographic and histopathologic results. The data revealed evidence of clear aortic valve dysfunction in WD mice as compared with control mice (interaction P < 0.001). MRI showed narrowing (14%, P < 0.05) of the orifice area, and this was also seen in histology (34%, P < 0.05), indicating more severe aortic stenosis after WD than in controls. Additionally, MRI revealed a reduction in the ejection fraction (EF) (-11%, P < 0.01), a result confirmed with echocardiography (-27%, P < 0.001) in mice fed with WD. EF detected by MRI and echocardiography also correlated strongly with the degree of stenosis assessed by histology. CONCLUSIONS: Cine-MRI can be used for quantitative analysis of the aortic valve orifice over the cardiac cycle in mice. MRI showed the cusps clearly, and we were able to detect aortic valve dysfunction over time through the cardiac cycle.


Assuntos
Valva Aórtica/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Animais , Antígenos de Diferenciação/metabolismo , Valva Aórtica/patologia , Valva Aórtica/fisiopatologia , Apolipoproteínas B/metabolismo , Eletrocardiografia , Hipercolesterolemia/patologia , Imageamento por Ressonância Magnética , Camundongos , Receptores de LDL/metabolismo , Proteínas S100/metabolismo , Volume Sistólico
5.
J Cardiovasc Magn Reson ; 20(1): 34, 2018 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-29879996

RESUMO

BACKGROUND: Two days after myocardial infarction (MI), the infarct consists mostly on necrotic tissue, and the myocardium is transformed through granulation tissue to scar in two weeks after the onset of ischemia in mice. In the current work, we determined and optimized cardiovascular magnetic resonance (CMR) methods for the detection of MI size during the scar formation without contrast agents in mice. METHODS: We characterized MI and remote areas with rotating frame relaxation time mapping including relaxation along fictitious field in nth rotating frame (RAFFn), T1ρ and T2 relaxation time mappings at 1, 3, 7, and 21 days after MI. These results were compared to late gadolinium enhancement (LGE) and Sirius Red-stained histology sections, which were obtained at day 21 after MI. RESULTS: All relaxation time maps showed significant differences in relaxation time between the MI and remote area. Areas of increased signal intensities after gadolinium injection and areas with increased TRAFF2 relaxation time were highly correlated with the MI area determined from Sirius Red-stained histology sections (LGE: R2 = 0.92, P < 0.01, TRAFF2: R2 = 0.95, P < 0.001). Infarct area determined based on T1ρ relaxation time correlated highly with Sirius Red histology sections (R2 = 0.97, P < 0.01). The smallest overestimation of the LGE-defined MI area was obtained for TRAFF2 (5.6 ± 4.2%) while for T1ρ overestimation percentage was > 9% depending on T1ρ pulse power. CONCLUSION: T1ρ and TRAFF2 relaxation time maps can be used to determine accurately MI area at various time points in the mouse heart. Determination of MI size based on TRAFF2 relaxation time maps could be performed without contrast agents, unlike LGE, and with lower specific absorption rate compared to on-resonance T1ρ relaxation time mapping.


Assuntos
Cicatriz/diagnóstico , Meios de Contraste/administração & dosagem , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico por imagem , Miocárdio/patologia , Animais , Compostos Azo , Biópsia , Cicatriz/patologia , Corantes , Modelos Animais de Doenças , Feminino , Camundongos Endogâmicos C57BL , Infarto do Miocárdio/patologia , Necrose , Valor Preditivo dos Testes , Coloração e Rotulagem/métodos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA